loading spinner

Category

Departments

Request a Call Back

Let us give you a call, for your convenience. Please enter your name and contact number in the box below and hit the button. This service is for customer enquiries only.

Your details :

Apollo Pro Dynamic Full Replacement Mattress System - Very High Risk

HSAPH059

Very High RiskThe Apollo Pro dynamic mattress benefits from a uniquely designed cell configuration in order to ensure the best possible pressure relieving qualities. The patented cell technology offers a revolutionary 'Very High Risk' dynamic mattress, ensuring optimum patient comfort and safety.

More details

£ 1,552.50 VAT excl.

  • Very High RiskThe Apollo Pro dynamic mattress benefits from a uniquely designed cell configuration in order to ensure the best possible pressure relieving qualities. The patented cell technology offers a revolutionary 'Very High Risk' dynamic mattress, ensuring optimum patient comfort and safety.


     

    Key Features


    • 39 stone weight limit
    • Heel protector
    • Very high risk replacement mattress
    • ‘Cell in Cell’ replacement system with static base
    • Adjustable weight settings
    • Timed static switch to assist in patient transfer and for good nursing practise
    • Auto-lockout function
    • Designed for users at very high risk, or have existing tissue damage
      (pressure ulcer grade 1-4)
    • Manual adjustment for to user’s body shape and position for optimum
      pressure care
    • Dynamic  therapy for alternating action for lower interface pressures and
      gentle capillary stimulation
    • Humidity management to help prevention of tissue breakdown and skin maceration
    • Enhanced shear and friction protection
    • Autofirm option to inflate the mattress to maximum pressure to allow safe
      patient transfer
    • Alternating cycle time variances to offer different periods of pressure relief 
    • Audio and visual alarms to differentiate between low pressure, power
      failure and system failure errors
    • Seat switch to increase the pressure in the sacrum area for when the patient
      is sat upright
    • Welded vapour permeable multi stretch PU cover to prevent fluid ingress and internal mattress contamination
    • Clinically effective against bacteria / viruses with proven resistance to MRSA
    • Fire retardant to Standards BS7175 Crib 5
    • CPR function to ensure rapid deflation of mattress
    • The mattress cover can be wipe down or completely removed and laundered up to 95°C to aid decontamination protocols
     

    Specifications


    Product Code: PB-059

    Max Weight Limit: 39 stone / 247.6 Kg

    Min Weight Limit: 6 stone / 40 Kg

    Risk Factor: Very High Risk

    Warranty: 2 years

    Cell Configuration:  3 static, 10 figure of 8 cells and 7 pairs of heel guard cells

    Operating Cycle:  Option of either 10, 15, 20, 25 minutes

    Pressure Range: 20-60 mmHg

    Mattress Dimensions (inflated): 200cm x 92cm x 20cm

    Mattress Weight: 5 Kg

    Power Unit Dimensions:  37cm x 13.5cm x 25cm

    Power Unit Weight: 4.2 Kg


    Electrical 

    EMC Standards:  CISPR 11 Class B, IEC 61000-3-2, IEC 61000-3-3,
    IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5,
    IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11

    Voltage: AC230V 50Hz

    Noise Level: Below NC27

    Fuse Input: 12w

    Fuse: External